DATA SHEET OF MICRO CRYSTALLINE WAX - GRADE "IOCU SW 1010" |
SL No |
Characteristics |
Unit |
Method |
Normal
Results |
1 |
Drop melting point |
°C |
IP-133 /ASTM
D-127 |
79 to 82 |
|
|
|
|
|
2 |
Oil content (Max) |
%mass |
IP-158 /ASTM
D-721 |
Below 2 |
|
|
|
|
|
3 |
Colour (Max) |
--- |
ASTM D-1500 |
0 |
|
|
|
|
|
4 |
Needle
Penetration, 1/10mm (25°C, for 5 Sec with 100g) |
--- |
P:93 / IP:49 /
ASTM 1321 |
30 to 35 |
|
|
|
|
|
5 |
Viscosity at 98.9°C |
Cst |
P:25 |
24 |
|
|
|
|
|
6 |
Flash Point, COC, (Min) |
°C |
ASTM D-92 |
260 to 275 |
|
|
|
|
|
7 |
Odour |
--- |
Physical |
Odourless |
|
|
|
|
|
8 |
Acidity (Inorganic) |
mgKOH/g |
P:2 |
0 |
|
|
|
|
|
9 |
Ash Content |
% Mass |
IP 223 |
0.01 |
|
|
|
|
|
10 |
Congealing Point |
°C |
---- |
70 |
|
|
|
|
|
11 |
UV visible Absorbtion |
|
|
|
Path length (Max): |
|
|
|
280-289 Millimicrons |
nm |
|
0.08 |
290-299 |
nm |
ASTM |
0.06 |
300-359 |
nm |
D-2008 |
0.05 |
360-400 |
nm |
|
0.02 |
|
|
|
|
|
12 |
Toxic & Dermatic Action |
--- |
Non Toxic &
Non Dermatic |
Complies
(Passes) |
|
|
|
|
|
13 |
Melting Point |
°C |
---- |
73 |
|
|
|
|
|
14 |
Appearance |
--- |
Visual |
Slabs |
|
|
|
|
Free from
foreign Particals |
|
|
|
Packing: 5 slabs per carton, each slab weighing about 5.2 Kg
Each carton 26 Kg net |
|
|
|
NON-WARRANTY OF RESULTS (Please use after tests and approval) |
No warranties, express or implied, or warrenties of
merchantability or fitness for a particular use, are made |
by Chowdhary Udyog with respect to any products described or
information set forth herein. Our recomme - |
-
ndations for its use are purely based on tests believed reliable. The sample
unless specified as IP is meant |
for industrial use only. Since the use is beyond our control we
do not guarantee the results whether or not |
such use is in accordance with directions. It is also
unedrstood that the quality and specification of the sample |
are
typical only. The information presented herein is based on the evaluation
carried out in our in house Lab & on the |
tests carried out by outside inspection
agencies and the data available therefrom and believed to be correct. |
Quality comparable to Witco's (USA) "W 445",
Schumann Sasol's (Germany) "3971" & Honeywell's (USA)
"OK-139" |
|
|
|
|
|