DATA SHEET OF MICRO CRYSTALLINE WAX - GRADE "IOCU SW 1610 EP10" |
| SL No |
Characteristics |
Unit |
Method |
Normal Results |
| |
|
|
|
|
| 1 |
Drop melting point |
°C |
IP-133 /ASTM
D-127 |
84 |
| |
|
|
|
|
| 2 |
Oil content (Max) |
%mass |
IP-158 /ASTM
D-721 |
0.95 |
| |
|
|
|
|
| 3 |
Colour (Max) |
--- |
ASTM D-1500 |
0 |
| |
|
|
|
|
| 4 |
Needle
Penetration, 1/10mm (25°C, for 5 Sec with 100g) |
--- |
P:93 / IP:49 /
ASTM 1321 |
12 |
| |
|
|
|
|
| 5 |
Viscosity at 98.9°C |
Cst |
P:25 |
12 |
| |
|
|
|
|
| 6 |
Flash Point, COC, (Min) |
°C |
ASTM D-92 |
252 |
| |
|
|
|
|
| 7 |
Odour |
--- |
Physical |
Odourless |
| |
|
|
|
|
| 8 |
Acidity (Inorganic) |
mgKOH/g |
P:2 |
0 |
| |
|
|
|
|
| 9 |
Ash Content |
% Mass |
IP 223 |
0.01 |
| |
|
|
|
|
| 10 |
Congealing Point |
°C |
---- |
80 |
| |
|
|
|
|
| 11 |
UV visible Absorbtion |
|
|
|
| Path length (Max): |
|
|
|
| 280-289 Millimicrons |
nm |
|
0.08 |
| 290-299 |
nm |
ASTM |
0.06 |
| 300-359 |
nm |
D-2008 |
0.05 |
| 360-400 |
nm |
|
0.02 |
| |
|
|
|
|
| 12 |
Toxic & Dermatic Action |
--- |
---- |
Complies
(Passes) |
| |
|
|
|
|
| 13 |
Melting Point |
°C |
---- |
82 |
| |
|
|
|
|
| 14 |
Appearance |
--- |
Visual |
Free from
foreign Particals |
| Packing: 5
slabs per carton, each slab weighing about 5 Kg. Each carton 25 Kg approx. |
NON-WARRANTY OF RESULTS (Please use after tests and approval) |
| No warranties, express or implied, or warrenties of
merchantability or fitness for a particular use, are made |
| by Chowdhary Udyog with respect to any products described or
information set forth herein. Our recomme - |
| -
ndations for its use are purely based on tests believed reliable. The sample
unless specified as IP is meant |
| for industrial use only. Since the use is beyond our control we
do not guarantee the results whether or not |
| such use is in accordance with directions. It is also
unedrstood that the quality and specification of the sample |
| are
typical only. The information presented herein is based on the evaluation
carried out in our in house Lab & on the |
| tests
carried out by outside inspection agencies and the data available therefrom
and believed to be correct. |
|
|
|
|
|
|